Copper Sulphate Testing of Aluminium Tube

This test applies only to lacquered aluminium tube

Regent

Copper sulphate solution mixed as follows

  • Copper sulphate (Cuso4. 5H2O) 198.2 g
  • Hydrochloric acid Conc. 51 ml
  • Distilled water 1 litre

Procedure

  • Selected five samples at random from the sample lot
  • Take a sample tube and pour copper sulphate solution with ¼ of the open-end
  • Place the tube aside for 1 minute
  • After the time has elapsed, drain copper sulphate from the tube.
  • Cut the tube from the shoulder
  • Flatten the tube well
  • Check the tube surface for the presence of black spots
  • Black spot will present the exposed aluminium surface
  • There shall not be the presence of black spots